46 Program features
2. PQ (power/flow) curve based flow calculation
In the PQ curve based flow calculation, the user can define a PQ (power/flow)
performance curve that is used as the basis for the calculation or a differential
pressure based flow feedback. The figure below shows the PQ performance
curve of the pump for the flow calculation function.
Notes:
• The flow calculation function cannot be used for invoicing purposes.
• The flow calculation function cannot be used outside the normal operating
range of the pump.
• Power points in PQ curve are expected to be in ascending order
(P1 < P2 < P3 < P4 < P5).
• Flow points in PQ curve are expected to be in ascending order
(Q1 < Q2 < Q3 < Q4 < Q5).
3. HQ (head/flow) curve based flow calculation
In the HQ curve based flow calculation, the user can define a HQ (head/flow)
performance curve that is used as the basis for the calculation or a differential
pressure based flow feedback.
P [kW] or P [hp]
Q [m
3
/h] or Q [gpm]
2
4
5
3
1