Advanced Programming
Page 122
ORB Operating Manual – Issue 1.0
Home Function
The Home function provides a quick method of setting fixture
parameters to their ‘home’ position, ie brightness to full, colour to
white, no gobo, no prisms, shutter open, pan/tilt to mid-position
etc. The homed parameters are automatically tagged.
Select the fixture(s) required, then enter one of the following
commands:
HOME
(homes all fixture parameters; removes all effects)
COLOUR 0 ENTER
(homes colour parameters; removes colour effects)
BEAM 0 ENTER
(homes beamshape parameters; removes beamshape effects)
POSITION 0 ENTER
(homes position parameters; removes position effects)
EFFECTS 0 ENTER
(removes all effects)
Copying Fixture Data
You can copy fixture data from a programmed cue or from another
fixture in the programmer. The data for all fixture parameters can
be copied, or just those for a particular attribute by using the
following commands:
1 @ CUE C ENTER
Copies all the fixture parameter
values from the cue C to fixture
1.
1 @ S/C ENTER
Copies all the fixture parameter
values from the cue S/C to
fixture 1.
1 COLOUR @ S/C ENTER
Copies
the
colour
fixture
parameter values from cue S/C
to fixture 1.
1 COPY TO 2 ENTER
Copies all the fixture parameter
values from fixture 1 to fixture
2.
1 BEAM COPY TO 2 ENTER
Copies the beamshape
parameter values from fixture 1
to fixture 2.
1 COPY TO 2 THRU 10 ENTER
Copies all fixture parameter
values from fixture 1 to fixtures
2 to 10.
1 COPY TO GROUP N ENTER
Copies all fixture parameter
values from fixture 1 to the
fixtures in group N.
Summary of Contents for ORB