Submasters
ORB Operating Manual – Issue 1.0
Page 107
Fade Times on Submasters
Some blurb about fade times on submasters
Editing Submasters
To edit a SUB enter the following command:
LOAD SUB n ENTER
This allows you to load the contents of the submaster back into the
programmer, adjust the programmed channel levels and times as
required and then save the data back into the original submaster by
pressing the UPDATE key.
Alternatively you can use the UPDATE functionality to UPDATE a Sub
through the Update Options Window – see Page 78 for full details.
Previewing Submasters
It is possible to preview the contents of a submaster on the
monitor. To do this, enter the syntax:
VIEW SUB n ENTER
Copying Submasters
A submaster can be copied to another location by entering:
SUB x COPY TO y ENTER
The submaster will be copied together with any names, fade times
and special settings. The new copy can then be manipulated as
required.
Moving Submasters
A submaster can be moved from one location to another by
entering:
SUB x MOVE TO y ENTER
The submaster will change location automatically.
Deleting Submasters
Individual submasters can be deleted (cleared) by entering one of
the following commands:
DELETE SUB n ENTER
DELETE SUB x / y ENTER
SUB n DELETE
Summary of Contents for ORB
Page 1: ...ORB OPERATING MANUAL...