6-49
IM AQ1300-01EN
Manual T
est Settings (Manual)
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Start Pattern comparison from Payload of Tx Frame
Select whether or not to set the Tx frame payload as the comparison location.
• Selected: The Tx frame payload is set as the comparison location.
• Cleared: The Tx frame payload is not set as the comparison location. You must set the payload
comparison location as an offset value.
Offset
You must set the payload comparison location as an offset value.
Range: Byte 0 to 255
Rx Base Filter Setting
Frame Structure
The specified frame structure is displayed.
Detail
Press to configure the Rx frame settings in the Frame Setting screen. For details, see section 6.5.
Filter 1 and 2
Select whether or not to use Rx base filters 1 and 2.
• Selected: The Rx base filter is used.
• Cleared: The Rx base filter is not used.
The selected Rx base filter type is displayed.
Detail
Press to configure the Rx base filter settings in the Rx Base Filter Setting screen. For details, see
section 6.5.
Combination
Set the combination condition for Rx base filters 1 and 2.
• AND: The conditions of the Rx base filters are combined using AND logic.
• OR: The conditions of the Rx base filters are combined using OR logic.
Condition
Select the type of frame to allow to pass through the Rx base filters.
• Match: Frames that match the filter conditions pass through the filters.
• Mismatch: Frames that do not match the filter conditions pass through the filters.
6.9 Configuring a BERT