6-51
IM AQ1300-01EN
Manual T
est Settings (Manual)
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Save a statistic log after the measurement
Set whether to automatically save statistical results.
This feature is supported in firmware version (FW Ver.) R1.08.01.001 and later.
• Selected: The statistical log file will be saved. Selecting the Execute Logging check box will
automatically select this check box.
• Cleared: The statistical log file will not be saved.
Note
You cannot set this feature if the Save measurement results and Statistics Log check box on the
measurement screen in section 6.11 is selected.
Statistics Log Items
You can log statistics for up to four items.
Statistics Item Set
Set the statistics log item by group and item.
For information about the items that you can specify, see section 1.8.
Current Values of Statistical Items
Statistics logs can be recorded using the current values of statistical items of each second.
This feature is supported in firmware version (FW Ver.) R1.08.01.001 and later.
• Selected: Statistics logs are recorded using current values.
• Cleared: Statistics logs are recorded using maximum values during the logging time. This is
the conventional method.
The statistical items that are logged using current values are listed below.
Group Name
Statistical Item
Latency
Max IFG(µs, bit)
Min IFG(µs, bit)
Avg IFG(µs, bit)
Max Latency(µs)
Min Latency(µs)
Avg Latency(µs)
Rx Channel (1 to 8)
Max Latency(µs)
Min Latency(µs)
Avg Latency(µs)
The word “Current” is attached to the item names in the statistical log files (CSV format).
Start Time
2012/4/1 09:00
Time (YY/MM/DD/hh/mm:ss)
Latency:[Current] Max IFG (µs)
2012/4/1 09:00::00
0
2012/4/1 09:00::01
1
2012/4/1 09:00::02
0
6.10 Configuring the Statistics Log