6-35
IM AQ1300-01EN
Manual T
est Settings (Manual)
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Rx QoS Filter Setting Screen
Press
Detail
next to an Rx QoS filter to display the following screen.
Set the method
(Field, Offset).
Set the field.
This setting is valid when Method is set to
Field.
(VLAN-ID, VLAN-CoS, IPv4-ToS,
IPv4-DSCP, IPv6-TrafficClass,
IPv6-DSCP, L4-DP, L4-SP)
The items that you can select vary
depending on how the frame structure and
VLAN settings in the Rx QoS Setting
screen are configured.
Set the offset.
This setting is valid when Method is set to
Offset.
Offset (0-255 bytes).
Bit/Mask
Bit offset (0-31 bits)
Bit width (1-32 bits)
This setting appears when Bit/Mask is set
to Bit.
Set the byte length (1-4 bytes) and the
master pattern.
This setting appears when Bit/Mask is set
to Mask.
Rx Setting Screen
Press the
Detail Setup
soft key and then the
Rx Setting
soft key to display the following screen.
Set the oversize threshold
(65-10000 bytes).
Select this check box to detect payload
errors.
Set the offset (Match to Tx Setting,
Manual).
Set the offset byte (byte 0-255).
This setting is valid when offset is set to
Manual.
Set the frames to take statistics of
(Test Frame Only, All Frames).
Configure the frames.
►
section 6.5
Frame structure indication
Set the Rx base filter methods.
Configure the Rx base filters.
►
section 6.5.
Select a check box to use the
corresponding Rx base filter.
Set how Rx base filters 1 and 2 are
combined (AND, OR).
Set the frame pass condition
(Match, Mismatch).
Note
The AQ1300/AQ1301 will receive the type of frames specified by the Frame Structure setting.
6.7 Configuring a QoS Test