Test Window Size
Set the sample width for the calculation of the delay variation value. The AQ1300/AQ1301
statistically processes a delay variation value for each sample width. For details, see section 1.16,
“RFC2544 Measurement.”
• 100ms
• 500ms
• 1s
• 10s
• Test duration
Resolution
Set the resolution for the calculation of the delay variation value. If you set Resolution to Auto, the
AQ1300/AQ1301 automatically selects the value of the setting when it performs the measurement.
For details, see section 1.16, “RFC2544 Measurement.”
• Auto
• 0.05ms
• 0.1ms
• 0.5ms
• 1.0ms
• 2.5ms
• 5.0ms
Note
If the delay variation changes greatly depending on the test frame length, the percentile value may not be
measurable when the resolution is set to Auto. If this is the case, set the resolution to a specific value, and
perform the measurement.
Calculation Criterion for Result
Set the threshold value that is used to calculate the statistical result of the delay variations. For
details, see section 1.16, “RFC2544 Measurement.”
• 50Percentile
• 75Percentile
• 90Percentile
Pass/Fail Judge
Set whether to perform pass/fail judgments on the packet jitter test result.
• Selected: Pass/fail judgments are performed.
• Cleared: Pass/fail judgments are not performed.
Note
If you want to perform pass/fail judgments, enable the pass/fail judgment setting in the optional measurement
settings as well.
Threshold Criterion
If you select to perform pass/fail judgments on the packet jitter test result, set the judgment
threshold.
Range: 0.05 to 300.00 ms