Explanation
Advance Setup Screen
Select setup file after selecting RFC2544
Select whether to display the Select Setup File screen after you select RFC2544 on the Test Menu.
• Selected: The Select Setup File screen is displayed.
• Cleared: The Select Setup File screen is not displayed. The previous settings are automatically
selected.
Allow to Change the Test Setup
Select whether to allow the Test Setup screen settings to be changed.
• Selected: The Test Setup screen settings can be changed.
• Cleared: The Test Setup screen settings cannot be changed.
Measurement Setup Screen
Measurement START Condition
Request ARP/NDP (During RFC2544 tests, this is fixed to selected and appears dimmed.)
For ARP (IPv4) and NDP (IPv6) destination MAC addresses, select whether to use an ARP or NDP
request to acquire the MAC address when the START key is pressed. This setting is valid when the
test layer is L3-IPv4 or L3-IPv6.
• Selected: An ARP/NDP request is sent.
• Cleared: An ARP/NDP request is not sent.
Not start the measurement when Link is down. (During RFC2544 tests, this is fixed to
selected and appears dimmed.)
Select whether to start measurement when the START key is pressed and a linkdown is detected.
• Selected: Measurement is not started when a linkdown is detected.
• Cleared: Measurement is started when a linkdown is detected.
Measurement STOP Condition
When Link Down is detected (During RFC2544 tests, this is fixed to selected and appears
dimmed.)
Select whether to stop measurement when a linkdown is detected during measurement.
• Selected: Measurement is stopped when a linkdown is detected.
• Cleared: Measurement is not stopped when a linkdown is detected.
When L2 Error is detected
Select whether to stop measurement when an L2 error is detected during measurement.
• Selected: Measurement is stopped when an L2 error is detected.
• Cleared: Measurement is not stopped when an L2 error is detected.
When Fail Result is detected
Select whether to stop measurement when the result of the test currently being performed produces
a fail judgment.
• Selected: Measurement is stopped when the test result produces a fail judgment.
• Cleared: Measurement is not stopped when the test result produces a fail judgment.