12-15
IM AQ1300-01EN
E-OAM T
est
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
App
Index
Auto Tx RDI
Set whether to transmit an RDI frame to the network device at the destination address when a loss
of continuity is detected (CCM frame is not received).
• Selected: An RDI frame is transmitted.
• Cleared: An RDI frame is not transmitted.
Tx START Condition
The CCM frame transmission and reception timing can be synchronized within the same
maintenance domain.
• First Rx CCM: After a CC test is started, CCM frame transmission starts when the AQ1300/
AQ1301 receives the first CCM frame from the target MEP.
• Test Start: CCM frame transmission starts when the specified wait time elapses after the START
key is pressed.
• Wait Time: Set the wait time for when the Tx START Condition is set to Test Start.
0 to 999 s (approx. 16 minutes)
CCM Frame Reception Settings
Rx
Set whether to receive CCM frames during CC tests.
• Selected: CCM frames are received during CC tests.
• Cleared: CCM frames are not received during CC tests.
Target MEP ID
Select how to set the ID number of the target network device (MEP) to receive CCM frames from.
• First CCM: After a CC test is started, the AQ1300/AQ1301 receives the first CCM frame, reads
the MEP ID in the frame, and saves it as its target MEP.
• Designation:
Manually enter the MEP ID.
0
to
8191
MEP ID table
Select the ID value from the MEP ID table. Displayed when the method of setting the ID number is
set to Designation.
12.6 Configuring the CC Test