CABLE ROUTING
2-36
1. Radiator inlet hose
2. Radiator
3. Radiator outlet hose
4. Radiator cap
5. Coolant reservoir hose
A. Point the ends of the hose clamp inward. Make
sure that the ends of the hose clamp do not
contact the coolant reservoir hose. Position the
hose clamp 3 mm (0.12 in) or more away from the
end of the radiator inlet hose. Make sure not to
install the hose clamp on the raised portion of the
hose fitting.
B. Align the yellow paint mark on the radiator inlet
hose with the projection on the radiator pipe. Install
the radiator inlet hose onto the radiator pipe so that
the hose contacts the projection on the pipe.
C. Point the ends of the hose clamp rearward.
Position the hose clamp 3 mm (0.12 in) or more
away from the end of the coolant reservoir hose.
Make sure not to install the hose clamp on the
raised portion of the hose fitting.
Summary of Contents for Tenere 700 2020
Page 1: ...2020 SERVICE MANUAL T n r 700 XTZ690 XTZ690 U BW3 F8197 E0...
Page 2: ......
Page 6: ......
Page 8: ......
Page 56: ...CABLE ROUTING 2 33 Hydraulic unit assembly top and left side view 1 2 3 4 3 4...
Page 58: ...CABLE ROUTING 2 35 Radiator front and right side view A B C 1 2 3 3 4 5...
Page 60: ...CABLE ROUTING 2 37 Radiator left side view A B C D D F E G 1 1 2 2 3 4 5 6 6 7 5...
Page 62: ...CABLE ROUTING 2 39...
Page 65: ......
Page 213: ...CYLINDER HEAD 5 26...
Page 252: ...CRANKCASE 5 65 a 1 2 2 b 45 10 1...
Page 292: ...WATER PUMP 6 15...
Page 308: ...THROTTLE BODIES 7 15...
Page 311: ......
Page 317: ...IGNITION SYSTEM 8 6...
Page 325: ...CHARGING SYSTEM 8 14...
Page 329: ...LIGHTING SYSTEM 8 18...
Page 337: ...SIGNALING SYSTEM 8 26...
Page 393: ...FUEL INJECTION SYSTEM 8 82...
Page 407: ...IMMOBILIZER SYSTEM 8 96...
Page 452: ...ELECTRICAL COMPONENTS 8 141...
Page 469: ......
Page 470: ......