SmartPAC PRO Servo User Manual
1147100
Chapter 5
– Program Mode
123
Green Sensors
A sensor input set to “green” must turn on, at least momentarily, within the Ready signal and be off,
at least momentarily, at some point outside the Ready signal, Figure 5-18.
Figure 5-18
. Ready Signal Programming for a “Green” Sensor
Green Quick Check Sensors
A sensor input set to “green quick check” must turn on, at least momentarily, within the Ready signal
and may not turn off outside the Ready signal, Figure 5-19. In other words, the sensor must turn on
and turn off within the Ready signal.
Figure 5-19
. Ready Signal Programming for a “Green Quick Check” Sensor