SmartPAC PRO Servo User Manual
1147100
Chapter 2
– Installation
45
2.
Making sure that you are grounded, install the new board by plugging it into the appropriate
connector. Connectors are keyed, so you can only plug in the boards in one direction.
3.
When the board is properly seated, screw it down to the four standoffs, using the screws that
came with the kit.
4.
Remove the connector(s) from the board, one connector for an 8-sensor or 8-cam unit, two
connectors for a 16-sensor or 16-cam unit, four connectors for a 32-sensor unit. Terminal block
assignments for the different boards are as follows:
•
DiProPAC 8: Sensors 1-8 to TB554
•
DiProPAC 16: Sensors 1-8 to TB554, sensors 9-16 to TB554
•
DiProPAC 32: Sensors 1-8 to TB554, sensors 9-16 to TB554, sensors 17-24 to TB555, and
sensors 25-32 to TB555
•
ProCamPAC 8: Cam channels 1-8 to TB401
•
ProCamPAC 16: Cam channels 1-8 to TB451, channels 9-16 to TB452
5.
Wire the connector(s) to the appropriate component(s). For the DiProPAC board, wire the
connector(s) to the DiPro Sensor Interface, following the instructions in
Sensor Interface to SmartPAC PRO Servo
, page 45. For the ProCamPAC board, wire the
connector(s) to the ProCam Output assembly, following the procedure in
6.
Plug the connector(s) back into their sockets on the board.
7.
Verify that you have installed the board(s) properly by performing
, page 57. You need to complete this procedure before you can use
SmartPAC PRO Servo.
Connecting DiPro Sensor Interface to SmartPAC PRO
Servo
To connect your DiPro die protection sensors through the DiPro Sensor Interface (DSI) 2, refer to
Table 2-3, below, to wire sensors 1-8
Table 2-4, page 47, to wire sensors 9-16
Table 2-5, page 48, to wire sensors 17-24
Table 2-6, page 48, to wire sensors 25-32.
Wiring diagrams (Figure 4 for sensors 1-16, Figure 5 for sensors 17-32) are provided at the end of the
manual. Terminate cable shields to ground studs close to the point of entry into the enclosure. Refer
to the DSI 2 manual for more information.
NOTICE
DSI 2 NOT COMPATIBLE WITH LOW-IMPEDANCE SENSORS
If any of your sensors are low-impedance types, they must be wired directly to DiProPAC. Low-
impedance sensors cannot be wired to DSI 2.
Summary of Contents for SmartPAC PRO Servo
Page 2: ......
Page 4: ......
Page 14: ......
Page 16: ......
Page 18: ......
Page 26: ...1147100 SmartPAC PRO Servo User Manual 26 Chapter 1 Introduction ...
Page 70: ...1147100 SmartPAC PRO Servo User Manual 70 Chapter 3 Displays and Operating Modes ...
Page 158: ...1147100 SmartPAC PRO Servo User Manual 158 Chapter 5 Program Mode ...
Page 204: ......
Page 206: ......
Page 208: ......
Page 210: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......