1147100
SmartPAC PRO Servo User Manual
196
Appendix A
– Installing the Balluff Linear Transducer
Table A- 2. Balluff Linear Transducer Wiring
Pin # on TB402
ProCamPAC Linear Board
Wire Color *
Shield
Terminate shield drain wire at the ProCamPAC board
under a screw in one of the standoffs.
1 (+DATA)
Grey
2 (-DATA)
Green
3 (+CLK)
Yellow
4 (-CLK)
Pink
5 (+24VDC)
Brown
6 (GND)
Blue
* White is not used.
5.
Double-check connections, then plug the connector back into TB402. It plugs in only one way.