SmartPAC PRO Servo User Manual
120
Chapter 5
– Program Mode
Setting Batch Pre-Load Counts
If you are setting up a tool for gagging operations, you can specify a pre-load count for each
Batch counter on the Advanced Counter Mode Selections screen. This pre-load value displays in the
COUNT field for each Batch counter you specify, decreasing by that value the number of strokes (or
good parts) required to reach the preset value. You can reset these preload values in Run mode when
the Batch preset is reached (see COUNTERS, page 165) as long as you set the CHANGE COUNTS
parameter on the Security Access Menu in Initialization to PROGRAM AND RUN MODES (see
To set batch pre-load counts, do the following:
1.
Select the pre-load count value for the batch you want (e.g., Batch 1, Batch 2, etc.). The Numeric
Entry window displays.
2.
Key in a pre-load count value, following the directions in the window, and press ENTER. The
value you keyed in displays on the Advanced Counter Mode Selections screen.
3.
Make sure that the AUTO BATCH PRE-LOAD field is set to OFF.
4.
Press RESET to return to the Counter Mode Selections screen.
DIE PROTECTION (Optional)
(PROGRAM
– GO TO THE TOOL MANAGER – SELECT TOOL – EDIT TOOL – DIE PROTECTION)
CAUTION
Some Servo presses are capable of hitting the same part more than once at Bottom Dead Center
(BDC) before returning to the top of the stroke. You will have to note the angle ranges at which
repeated strokes occur. Any cams programmed within these ranges will actuate once for each hit.
Die protection ready signals programmed within these ranges will expect sensor actuation once for
each hit. If this is not feasible, please contact Wintriss Tech. Support to learn about new advanced
features.
Failure to comply with these instructions could result in property damage.
NOTICE
For help with the Die Protection Sensor Menu and screens accessible from it, press the HELP key
when the applicable screen is displayed.
This item, which appears on the Tool Program Menu only when DiProPAC 8 or DiProPAC 16 is
installed, enables you to program up to 8 or 16 die protection sensors. (When DiProPAC 32 is an
installed option, this menu item is subdivided into DIPROPAC 1-16 and DIPROPAC 17-32 entries–
see Programming DiProPAC 32 Sensors, page 136.) Settings are made via the Die Protection Sensor
Menu, Figure 5-17.
Summary of Contents for SmartPAC PRO Servo
Page 2: ......
Page 4: ......
Page 14: ......
Page 16: ......
Page 18: ......
Page 26: ...1147100 SmartPAC PRO Servo User Manual 26 Chapter 1 Introduction ...
Page 70: ...1147100 SmartPAC PRO Servo User Manual 70 Chapter 3 Displays and Operating Modes ...
Page 158: ...1147100 SmartPAC PRO Servo User Manual 158 Chapter 5 Program Mode ...
Page 204: ......
Page 206: ......
Page 208: ......
Page 210: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......
Page 218: ......
Page 219: ......
Page 220: ......
Page 221: ......
Page 222: ......
Page 223: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......