4-22
3.
Push outward on the lower part of the two
vacuum break mounting tabs, lift out at the
bottom, and remove the vacuum break
from the slots in the rear panel.
1.
Unplug washer or disconnect power.
2.
Remove the cabinet assembly from the
washer (see page 4-16 for the procedure).
4.
Disconnect the water fill hose from the
vacuum break.
NOTE:
Use a container to catch the water
from the hose.
Lift From Slots
Vacuum Break
REMOVING THE VACUUM BREAK
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Water Fill Hose
Vacuum Break
Vacuum Break
(View Of Rear Panel With Basket Removed)