5-13
THERMAL CUTOFF
(ELECTRIC DRYERS ONLY)
Refer to page 4-49 for the procedure for ser-
vicing the thermal cutoff.
The thermal cutoff is a non-resettable device.
The cutoff temperature is 178
°
C (352
°
F).
If the dryer does not heat and there is 240 VAC
to the dryer, perform the following test.
1. Unplug dryer or disconnect power.
2. Disconnect the wires from the thermal cut-
off.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the ther-
mal cutoff terminals. The meter should in-
dicate continuity (0
Ω
). If the meter indi-
cates an open circuit (infinite), replace both
the thermal cutoff and the high-limit ther-
mostat. In addition, check for a failed
heater element, or a blocked, or improper
exhaust system.
Thermal Cutoff
High-Limit
Thermostat
Heater Terminals
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Summary of Contents for ADVANTECH CAE2761K
Page 8: ...1 4 ...
Page 9: ...1 5 ...
Page 10: ...1 6 ...
Page 11: ...1 7 ...
Page 12: ...1 8 ...
Page 14: ...1 10 NOTES ...
Page 15: ...WASHER 2 1 ...
Page 22: ...2 8 ...
Page 29: ...2 15 Whirlpool Pt 3391910 ...
Page 42: ...2 28 ...
Page 54: ...2 40 ...
Page 68: ...4 10 285784 ...
Page 146: ...6 18 NOTES ...
Page 148: ...Full Console Model 7 2 ...
Page 149: ...Full Console Model 7 3 ...
Page 150: ...7 4 Stack Electric Dryers ...
Page 153: ...8 1 ...
Page 154: ...8 2 ...
Page 155: ...9 1 ...
Page 156: ...9 2 ...
Page 157: ...9 3 ...
Page 158: ...9 4 ...
Page 159: ...9 5 ...
Page 174: ... NOTES ...
Page 175: ... NOTES ...
Page 176: ... NOTES ...
Page 178: ...CORPORATION ...