5-9
HEATER (ELECTRIC
MODELS ONLY)
Refer to page 4-49 for the procedure for ser-
vicing the heater.
1. Unplug dryer or disconnect power.
2. Disconnect the wire connectors from the
heater terminal block.
3. Set the ohmmeter to the R X 1 scale.
4. Touch the ohmmeter test leads to the ter-
minals on the heater terminal block. The
meter should indicate between 7 and 12
Ω
.
5. Touch an ohmmeter test lead to an ele-
ment terminal block connection, and the
other test lead to the heater housing case.
The reading should be an infinite resis-
tance (open circuit). A resistance reading
indicates a shorted coil.
Heater Terminal Block
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.