5-2
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MOTOR
Refer to page 4-11 for the procedure for ser-
vicing the motor.
1. Unplug washer or disconnect power.
2. Disconnect the plug from the motor con-
nector.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the fol-
lowing motor lead colors (shown on the
connector plate). The meter should indi-
cate as shown in the Motor Test Table.
5. Touch the ohmmeter test leads to the fol-
lowing motor switch connections. The
meter should indicate as shown in the
Motor Switch Test Table.
Motor Connector
R
BK
V
BU
OR
LOW
HIGH
START
V
BU
BU
BK
R
OR
CENTRIFUGAL
SWITCH
Y
W-BK
W
DRIVE MOTOR
WASHERS
FUNCTION
TEST TERMINALS
READING
LOW SPEED
V TO W-BK
18-26 OHMS
HIGH SPEED
BU TO W
1 - 1.5 OHMS
START WINDING
BK TO Y
5 - 10 OHMS
THERMAL
PROTECTOR
W TO W
0 OHMS
MOTOR TEST TABLE
STATE
TEST TERMINALS
READING
R TO BK
OR TO BU
OR TO V
R TO BU
R TO BK
OR TO BU
OR TO V
R TO BU
* SWITCH ARM CAN BE RELEASED BY REMOVING
THE SWITCH FROM THE MOTOR
MOTOR SWITCH TEST TABLE
AT REST
1 - 2 OHMS
OPEN
(INFINITE OHMS)
AT SPEED OR
SWITCH ARM
RELEASED*
1 - 2 OHMS
Summary of Contents for ADVANTECH CAE2761K
Page 8: ...1 4 ...
Page 9: ...1 5 ...
Page 10: ...1 6 ...
Page 11: ...1 7 ...
Page 12: ...1 8 ...
Page 14: ...1 10 NOTES ...
Page 15: ...WASHER 2 1 ...
Page 22: ...2 8 ...
Page 29: ...2 15 Whirlpool Pt 3391910 ...
Page 42: ...2 28 ...
Page 54: ...2 40 ...
Page 68: ...4 10 285784 ...
Page 146: ...6 18 NOTES ...
Page 148: ...Full Console Model 7 2 ...
Page 149: ...Full Console Model 7 3 ...
Page 150: ...7 4 Stack Electric Dryers ...
Page 153: ...8 1 ...
Page 154: ...8 2 ...
Page 155: ...9 1 ...
Page 156: ...9 2 ...
Page 157: ...9 3 ...
Page 158: ...9 4 ...
Page 159: ...9 5 ...
Page 174: ... NOTES ...
Page 175: ... NOTES ...
Page 176: ... NOTES ...
Page 178: ...CORPORATION ...