2-9
WARNING
GAS REQUIREMENTS
Explosion Hazard
Use a new AGA- or CSA-approved gas
supply line.
Install a shutoff valve.
Securely tighten all gas connections.
If connected to L.P. have a qualified
person make sure gas pressure does
not exceed 13
″
(33 cm) water column.
Examples of a qualified person include
licensed heating personnel, authorized
gas company personnel, and
authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
Dryer Installation Instructions
Burner input adjustments are not required
when the dryer is operated up to this eleva-
tion. When installed above 10,000 feet (3048 m),
a four percent (4%) reduction of the burner
BTU rating shown on the model/serial plate
is required for each 1,000 foot (305 m) increase
in elevation.
For assistance when converting to other
gas types and/or installing above 10,000
feet (3048 m) elevation, contact your local
service company.
3. Check that dryer is equipped with the cor-
rect burner for the particular type of gas
used. Burner information can be found on
the serial/rating plate in the door well of the
appliance. If this information does not agree
with the type of gas available, see your
dealer.
4. This dryer is equipped for use with NATU-
RAL GAS. It is certified by CSA Interna-
tional for manufactured, mixed and L.P.
(propane and butane) gases with appropri-
ate conversion. No attempt shall be made
to convert the appliance from the gas speci-
fied on the serial/rating plate for use with a
different gas without consulting the serving
gas supplier. A qualified service technician
must do conversion. Gas conversion kit
part numbers are listed on the gas valve
burner base.
5. Provide a
rigid gas supply line
of 1/2
″
IPS
pipe to the dryer location. If the total length
of the supply line is more than 20 feet (6.1 m),
larger pipe will be needed. For L.P. gas
usage, 3/8
″
approved copper tubing may
be used. Pipejoint compounds suitable for
use with LP gas should be used.
Observe all governing codes and ordi-
nances.
1. This installation must conform with local
codes, or in absence of local codes with the
National Fuel Gas Code ANSI Z223.1/NFPA
54 or the CAN/CGA - B149 installation codes.
2. The design of this dryer has been certified
by the CSA International for use at altitudes
up to 10,000 feet (3048 m) above sea level,
at the BTU rating indicated on the model/
serial plate.
Summary of Contents for ADVANTECH CAE2761K
Page 8: ...1 4 ...
Page 9: ...1 5 ...
Page 10: ...1 6 ...
Page 11: ...1 7 ...
Page 12: ...1 8 ...
Page 14: ...1 10 NOTES ...
Page 15: ...WASHER 2 1 ...
Page 22: ...2 8 ...
Page 29: ...2 15 Whirlpool Pt 3391910 ...
Page 42: ...2 28 ...
Page 54: ...2 40 ...
Page 68: ...4 10 285784 ...
Page 146: ...6 18 NOTES ...
Page 148: ...Full Console Model 7 2 ...
Page 149: ...Full Console Model 7 3 ...
Page 150: ...7 4 Stack Electric Dryers ...
Page 153: ...8 1 ...
Page 154: ...8 2 ...
Page 155: ...9 1 ...
Page 156: ...9 2 ...
Page 157: ...9 3 ...
Page 158: ...9 4 ...
Page 159: ...9 5 ...
Page 174: ... NOTES ...
Page 175: ... NOTES ...
Page 176: ... NOTES ...
Page 178: ...CORPORATION ...