4-6
REMOVING THE MONEY ACCEPTORS & METERCASE
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1.
Unplug washer or disconnect power.
2.
Unlock the service access door and re-
move it from the top of the metercase.
Coinslide
Assembly
Coinbox
Metercase
Access Door
Coinslide Switch
(inside) On
Coinslide
Extension
3.
To remove the coinslide assembly:
a) Using a 5/16
″
socket, unscrew the
retaining bolt from the money accep-
tor, and remove the bolt from inside the
metercase.
b) Remove the 5/16
″
hex-head screw from
the coinslide green ground wire that is
attached inside the metercase.
5/16
″
Retaining Bolt
Ground Wire