WESTLOCK CONTROLS CORPORATION
280 N. MIDLAND AVE., STE. 258, SADDLE BROOK, NJ 07663 TEL: 201-794-7650 FAX: 201-794-0913
www.westlockcontrols.com
10/5/2013
TECH-477/D.W.O. 21424
Page 193 of 206
13 Appendix B – Procedure to Remove Electronics Cover and
Electronic Canister
1. Remove the two screws (A & B) that secure the inner canister cover, unlock the latch by
pulling it up and remove the canister cover (see figures below).
2. Disconnect all connectors from electronics canister; make sure to note connector
locations. Remove the screw that secures canister housing and ground cable (C).
Remove the screw that secures ground cable (see figures below).
3. Remove the canister with electronics from ICoT enclosure.
INDICATED SCREW
SECURES COVER
AND HOUSING OF
CANISTER
LATCH
INDICATED SCREW
SECURES COVER
AND HOUSING OF
CANISTER
INDICATED SCREW
SECURES HOUSING OF
CANISTER AND GROUND
CABLE
CANISTER COVER
A
B
C