Specialized Concentrated Focused
「
76
」
Advantageous Functions
Position: nominal value, i.e. the theoretically arrived position driven by the pulses sent by the system
when there is no compensation;
Measured Value (P): the actually arrived position driven by the pluses sent by the system to move
forward when there is no compensation.
Measured Value (N): the actually arrived position driven by the pulses sent by the system to move
reversely when there is no compensation.
Lead Screw Error Compensation Tool
AxesErrEditor.exe is in Tools folder under installation directory (for example C:\Program Files\Weihong)
after software installation.
The main interface of AxesErrEditor.exe is as shown in Fig. 6-3:
Fig. 6-3 Main interface of AxesErrEditor.exe
Generally the value of lead screw error compensation can be measured by a laser interferometer, with
two ways for compensation.
1) File compensation. Select [Import File] under [File] menu, choose the compensation data
recorded by a laser interferometer to be imported in the pop-up dialog, and then save the data file
to corresponding configuration folder (for standard configuration, save the file to
―6B_std‖ under
―config‖ folder, for double-Y configuration, save it to ―6A_2Y"). In this way, automatic
compensation will be performed during machining in terms of the data in the file. Currently,
only .lin files are supported.