Specialized Concentrated Focused
「
126
」
Appendix
7.5. List of System Parameters
Parameter Name
Setting Range
Default
When
Enabled
Manu
Rapid jogging speed
1 ~ Min. value of max. speed of
all axes (mm/min)
1800
Immediately
Jogging speed
0.06 ~ Min. value of max. speed
of all axes (mm/min)
1200
Immediately
Stepping speed
0.06 ~ Min. value of max. speed
of all axes (mm/min)
1200
Immediately
MaxJogSpeedBeforeBackToRef
Point
1~5000 mm/min
3000
Immediately
Fixed Point
X machine coordiante
-99999~99999(mm)
0
Immediately
Y machine coordiante
-99999~99999(mm)
0
Immediately
Z machine coordiante
-99999~99999(mm)
0
Immediately
Bkref
Force homing before machining
Yes: Force;No: Not force
No
Immediately
X direction in coarse positioning
1: Positive; -1: Negative
-1
Immediately
Y direction in coarse positioning
1: Positive; -1: Negative
-1
Immediately
Z direction in coarse positioning
1: Positive; -1: Negative
-1
Immediately
X speed in coarse positioning
0.06 ~ 9000(mm/min)
1800
Immediately
Y speed in coarse positioning
0.06 ~ 9000(mm/min)
1800
Immediately
Z speed in coarse positioning
0.06 ~ 9000(mm/min)
1800
Immediately
X speed in precision positioning
0.06 ~ 6000(mm/min)
60
Immediately
Y speed in precision positioning
0.06 ~ 6000(mm/min)
60
Immediately
Z speed in precision positioning
0.06 ~ 6000(mm/min)
60
Immediately
Back space of X
0 ~ 1000(mm)
2
Immediately
Back space of Y
0 ~ 1000(mm)
2
Immediately
Back space of Z
0 ~ 1000(mm)
2
Immediately
XAxis Param
Axis direction
1: Positive; -1: Negative
1
After restart
Pulse equivalent
0.00000001 ~ 1000 (mm/p)
0.001
After restart
Check worktable stroke
Yes: Enable; No: Disable
Yes
After restart
Lower limit of worktable stroke
-999999 ~ Upper limit(mm)
-1000
After restart
Upper limit of worktable stroke
Lower limit ~ 999999(mm)
1000
After restart
Starting speed
0 ~ Max. speed(mm/min)
0
After restart
Max. speed
0 ~ Max. speed supported by
hardware(mm/min)
9000
Immediately
Max. acceleration
0 ~ 100000( mm/s
2
)
400
After restart
Max. jerk
0 ~ 100000( mm/s
3
)
10000
Immediately