Specialized Concentrated Focused
Appendix
「
113
」
7.4.9. Parameter Setting of DELTA ASDA-A2 Servo Driver
Para.
No.
Function
Format &
Range
Value
Description
P0-02
Driver
status
display
02
Monitor if the number of sent and
received pulse is correct by setting this
parameter. In Weihong control system,
the correct quantity of pulse sent by
control card is detected by pulse
inspection in order to determine whether
there is electrical interference.
P1-00
External
pulse
train input type
ZYX
102
X=2: pulse + direction;
Z=1: negative logic.
P1-01 Set control mode
ZYX1X0
0000
Z=0: during control mode switching, DIO
is maintaining the set value. Since
switching control mode is not used, Z=0;
Y=0: positive rotation (CCW) (from the
view of load);
Y=1: negative rotation (CCW)
X1X0=00: position control mode
P1-44
Electronic
Gear
Ratio
(Numerator)(N1)
1~32767
Need
calculation
N1/M= mechanical deceleration ratio × 4
× encoder pulses × pulse equivalent /
pitch.
Representative
value:
encoder
pulses=2500,
pitch
=5mm,
pulse
equivalent=0.001, deceleration ratio = 1,
calculation as below:
N1 / M = 2500×4×0.001/5 = 2/1, N1=2,
M=1;
When the multi-electronic gear ratio is not
used, P2-60 ~P2-62 are not required.
P1-45
Electronic
Gear
Ratio
(Denominator)(M)
1~32767
Need
calculation
P2-10
Digital Input Pin 1
(DI1)
X2X1X0
101
X1X0=01: digital input (DI1 = SON)
corresponds to 9th pin of CN1.
X2=1: set DI1 input as NO (normally
open) a-contact point.
P2-15
Function
setting
for digital input pin
DI6
X2X1X0
100
Default factory setting of DI6 and DI7 is
NC (normally closed) limit signal input;
driver can‘t run without being connected
to pin 32 and pin 31 of CN1.
X2=1: set DI6 and DI7 inputs as NO
a-contact points.
X1X0=00, limit input of driver is not used.