Specialized Concentrated Focused
「
110
」
Appendix
Para.
No.
Code
Function
Value
Description
3
CMX
Electronic gear
numerator
Need
calcul-
ation
CMX/CDV=command unit × servo motor resolution
× mechanical deceleration ratio / pitch of lead
screw.
E.G., pitch 5 mm, encoder resolution 10000, shaft
coupling direct drag, pulse equivalent 0.001 mm,
CMX/CDV=10000×0.001/5 = 2/1;
When pulse equivalent = 0.0005mm, CMX/CDV =
1/1.
Electronic gear ratio range: 1/50 ~ 500
4
CDV
Electronic gear
denominator
Need
calcul-
ation
18
*DMD
Status
display
selection
00XX
3: cumulative command pulses E: load inertia
When the parameter is set [3], monitor if the
number of sent and received pulse is correct by
setting this parameter. In Weihong control system,
the correct quantity of pulse sent by control card is
detected by pulse inspection to determine if there is
electrical interference.
21
*OP3
Function
selection
3
(command pulse
format selection)
0001
Set pulse command input form: pulse train+ sign,
negative logic
41
*DIA
Signal
input
SON-ON,
LSP-ON
and
LSN-ON
automatically
selection
0110
Bit 0: Servo-ON selection. [0]: servo on by external
input;
[1]: servo on all the time inside.
Bit 1: last signal of positive rotation range (LSP):
[1]: auto servo on inside, without external wiring.
Bit 3: last signal of negative rotation range (LSN):
[1]: auto servo on inside and no need of external
wiring.