Specialized Concentrated Focused
「
48
」
Menu Functions
[WCS Adjust]
The software supports manual edge finding function, which is the
―WCS Adjust‖ option under ―Mach‖
menu. Clicking on this option will eject a dialog, as shown in Fig. 4-39, including two-point positioning
and three-point positioning.
Two-point positioning: set a point O
‘ at the lower left of workpiece as the origin of new workpiece
coordinate system, and then a point A in the positive direction of X axis; thus, the new X axis O
‘A is
confirmed, the software automatically confirming the new Y axis by constructing a line perpendicular to
line O
‘A through O‘.
Three-point positioning: take the left bottom of workpiece as the temporary origin of new WCS, set a
point A and B in the positive direction of X axis to confirm the new X axis, and then set a point C in Y
axis, the software automatically confirming the new Y axis by constructing a line perpendicular to line
AB through point C. The foot of perpendicular O
‘ is the origin of new workpiece coordinate system.
CAUTION
Open the guide control when setting points in order to lead to the positioning
position.
Point A, B and C should all be on the positive axis.
In three-point positioning, A should be confirmed before B; otherwise, the axis
direction will be reversed.
Fig. 4-39 Work coordinate adjust dialog