System settings
90
Setting machine data
The position of the signal receiver and the place where the machine
works effectively are mostly different. To allow the machine to operate
correctly in the right place, you must run the following settings:
Go from one of the settings screens to the ISOBUS communication
menu.
See »Menu structure« on page 42.
Scroll to the "TC Implement Settings" screen.
In this screen, you can control and/or modify the settings of the
vehicle:
Mounted machine
•
Mounted machine
In this screen, you can run the following settings:
•
Offset connecting point with respect to the tractor track (A)
•
Distance from signal receiver to hard spreading discs (B)
The distance from signal receiver to spreading discs plus 1/3 x
working width. The control system can now calculate the correct
speed reduction for subsequent spreading on the headland and
during gored spreading.
With control by means of an external signal, it is often better to switch
off the automatic calibration when the dosing setting goes below a
specific value.
See section »Automatic calibration limit« on page 84.
S
Selector for mounted machines