If a system alarm appears on the control box screen, you must stop
immediately. The spreader cannot perform the requested function
adequately because the power supply is insufficient or the actuators
are not responding correctly. Fix the failure before working any further.
The supply voltage of the control system has gone below the set alarm
level. Repair the power supply, recharge the battery or replace it.
See also section »Supply voltage alarm« on page 81.
The left actuator cannot open. Check the feeder cable to the actuator
and whether hard objects or dirt are blocking the dosing units.
The left actuator cannot close. Check the feeder cable to the actuator
and whether hard objects or dirt are blocking the dosing units.
The right actuator cannot open. Check the feeder cable to the actuator
and whether hard objects or dirt are blocking the dosing units.
The right actuator cannot close. Check the feeder cable to the actuator
and whether hard objects or dirt are blocking the dosing units.
Weighcell alarms
If a weighcell alarm appears on the control box screen, you must stop
immediately. The spreader cannot carry out the requested function
adequately because the signal value conflicts with the saved
calibrated weighcell or reference sensor signal value.
When the spreader is at an angle, the reference sensor signal value
is higher than when the spreader is level. The signal value must be
highest when the spreader is level. The spreader reference sensor
must be recalibrated. Consult your dealer.
The weighcell signal value for an empty hopper is too low. Consult
your dealer.
The signal value for the displayed weight of a level machine does not
agree with the signal value when the machine is at an angle. Consult
your dealer.