Activities before spreading
113
Switch the control box on.
Press on the input field for the working width.
The popup keyboard appears on the screen.
Input the desired working width.
Press the OK key to confirm the working width.
Press the letter value of the discharge point.
Touch the new letter.
The new letter appears on the screen.
The selected application rate is entered in the same manner.
The selected step increments are entered in the same manner as
with over or under dosing.
See also section »Over and under dosing unit« on page 82.
When using a simulated driving speed the selected driving speed
is entered in the same manner.
If the tractor is equipped with a speedometer the actual driving speed
will appear in this field.
See also section »Driving speed signal« on page 77.
From the main screen:
Press the key switch on the main screen; you will now go to the
'Curve Calibration' screen.
Press on the input field for the dosing setting
Change the dosing setting in the pop-up keyboard.
Press the OK key to confirm the dosing setting.
The required flow rate is entered in the same manner.
The control system calculates the discharge curve with the preset
dosing setting and the relevant flow rate. With changing
circumstances, e.g. with a different driving speed, the control system
calculates the required flow rate. The relevant dosing setting is
determined and set through the discharge curve.
The control system will set the dosing units for the preset position
when spreading commences. The dosing setting will then be
corrected based on automatic calibrations performed by the control
system once every minute or after 75 kg have been spread. With
automatic calibration the control system determines the new
discharge curve. The dosing setting can be carefully adjusted with the
new dosing setting based on changing circumstances.
S
driving speed
S
Working width
S
Selected application
rate
S
Step size
S
Dosing setting
S
Flow rate
0,0
50,0
100,0
150,0
200,0
250,0
300,0
350,0
400,0
450,0
500,0
0
10
20
30
40
50
60
70
80
90
Flow rate (kg/min)
Dosing setting