Maintenance
198
Setting the weighing
sensor
The spreader is weighed in its entirety with the weighing linkage. The
empty weight is determined based on the spreader weight and all of
the accessories added together and included in the weighing system.
Must be set anew after the weighing sensor has been loosened!
The settings of the weighing sensor expire when it is removed. The
sensor must be set anew to the empty weight.
Preparing to set the weighing sensor
Pull the fastening bolts from the weighing sensor to.
Clean the spreader well internally and externally.
Connect the spreader to the tractor.
Raise the spreader to working height.
Set the spreader absolutely spirit level on the axle in length and
width.
Switch the control box on.
You start in the main screen.
Go to the "Hopper & Act Calibration" screen.
Check if the correct gross weight of the spreader has been entered
in the system.
See section »Hopper weight calibration« on page 92.
The basic weight of the spreader is:
•
without weighing linkage,
•
with added accessories.
Suppose that you have determined with the »Hopper weight
calibration« that your spreader, with the accessories added, and the
weighing linkage deducted from that, weighs 400 kg.
The correct gross weight value is shown in this screen.
Calculating the signal value
The desired signal value has already been calculated in this screen
as:
The signal value here is 400 x 6.7 = 2680.
S
Empty hopper signal value
S
Basic weight of the spreader
S
Empty hopper signal value =
S
Spreader gross weight x 6.7