Activities before spreading
138
Review and adaptation
The content of the separate tubes can differ 15% at most from the
average.
I
NDICATION
If the correction seems to be 2 letters too strong after repeating the
test, set the discharge point back by one letter.
Setting the disc height back to tray test
During the tray test the disc height above the troughs was set to 75
cm.
Imagine spreading with the disc height at 75 cm above the ground
or crops!
C
B
A
D
E
A
Good spreading pattern, the spreader has been adjusted
well
B
The spreader is not spreading widely enough.
Adjust the discharge opening 2 letters in the direction of
A
Repeat the test
C
The spreader is spreading too widely:
Adjust the discharge opening 2 letters in the direction of
U
Repeat the test
D
The spreader is not spreading widely enough (trapezium
spreading pattern):
Adjust the discharge opening 2 letters in the direction of
A
Repeat the test
E
The spreader is spreading too widely (trapezium spreading
pattern):
Adjust the discharge opening 2 letters in the direction of
U
Repeat the test