CG Drives & Automation,01-5326-01r3b
FFunctional Description
115
Fig. 87 Brake Output functions
Release Speed [33D]
Mechanical
Brake
Brake Relay
Output
Action must take place within
these time intervals
Brake release
time [33C]
Brake engage
time [33E]
Brake wait
time [33F]
Closed
On
Off
Open
Start
NOTE: Although this function is designed to operate a
mechanical brake via the digital outputs or relays (set to
brake function) controlling a mechanical brake, it can
also be used without a mechanical brake and hold the
load in a fixed position.