68
Operation via the Control Panel
CG Drives & Automation, 01-5326-01r03b
9.7
Programming example
This example shows how to program a change of the Acc.
Time set from 2.0 s to 4.0 s.
The flashing cursor indicates that a change has taken place
but is not saved yet. If at this moment, the power fails, the
change will not be saved.
Use the ESC, Prev, Next or the Toggle keys to proceed and
to go to other menus.
Fig. 74 Programming example
Menu 100 appears
after power-up.
Press Next for menu
[200].
Press Next for menu
[300].
Press Enter for menu
[310].
Press Next two times
for menu [330].
Press Enter for menu
[331].
Keep
key
pressed
until desired value has
been reached.
Save the changed
value by pressing
Enter.
100 0rpm
Stp
0.0A
NEXT
200 MAIN
SETUP
Stp
NEXT
300 Process
Stp
310 Set/View
Ref
Stp
NEXT
330 Run/Stop
Stp
331 Acc
Time
Stp
2.00s
331 Acc
Time
Stp
2.00s
Flashing
331 Acc
Time
Stp
4.00s
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...