CG Drives & Automation, 01-5326-01r3b
AnOut1 Max [5332]
This parameter is automatically displayed if User mA or
User V is selected in menu “AnOut1 Setup [532]”. The
menu will automatically adapt to current or voltage setting a
ccording to the selected setup. Only visible if [532] = User
mA/V.
Communication information
AnOut1 Bipol [5333]
Automatically displayed if User Bipol mA or User Bipol V is
selected in menu AnOut1 Setup. The menu will
automatically show mA or V range according to the selected
function. The range is set by changing the positive
maximum value; the negative value is automatically adapted
accordingly. Only visible if [512] = User Bipol mA/V.
Communication information
AnOut1 Function Min [5334]
With AnOut1 Function Min the physical minimum value is
scaled to selected presentation. The default scaling is
dependent of the selected function of “AnOut1 [531]”.
Table 31 shows corresponding values for the min and max
selections depending on the function of the analogue output
[531].
*) Fmin is dependent on the set value in menu
“Minimum Speed [341]”.
Communication information
Default:
20.00 mA
Range:
0.00–20.00 mA, 0–10.00 V
Modbus Instance no/DeviceNet no:
43254
Profibus slot/index
169/158
EtherCAT index (hex)
4cb6
Profinet IO index
19638
Fieldbus format
Long, 1=0.01 V,
0.01 mA
Modbus format
EInt
Default:
-10.00–10.00 V
Range:
-10.00–10.00 V, -20.0–20.0 mA
Modbus Instance no/DeviceNet no:
43255
Profibus slot/index
169/159
EtherCAT index (hex)
4cb7
Profinet IO index
19639
Fieldbus format
Long, 1=0.01 V,
0.01 mA
Modbus format
EInt
5332 AnOut 1 Max
Stp
20.0mA
5333 AnOut1Bipol
Stp
-10.00-10.00V
Default:
Min
Min
0
Min value
Max
1
Max value
User-defined 2
Define user value in menu [5335]
Table 31
AnOut
Function
Min Value
Max Value
Process Value Process Min [324] Process Max [325]
Speed
Min Speed [341]
Max Speed [343]
Torque
0%
Max Torque [351]
Process Ref
Process Min [324] Process Max [325]
Shaft Power
0%
Motor Power [223]
Frequency
Fmin *
Motor Frequency [222]
Current
0 A
Motor Current [224]
El Power
0 W
Motor Power [223]
Output Voltage 0 V
Motor Voltage [221]
DC voltage
0 V
1000 V
AnIn1
AnIn1 Function Min AnIn1 Function Max
AnIn2
AnIn2 Function Min AnIn2 Function Max
AnIn3
AnIn3 Function Min AnIn3 Function Max
AnIn4
AnIn4 Function Min AnIn4 Function Max
Modbus Instance no/DeviceNet no:
43256
Profibus slot/index
169/160
EtherCAT index (hex)
4cb8
Profinet IO index
19640
Fieldbus format
UInt
Modbus format
UInt
5334 AnOut1FCMin
Stp
Min
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...