CG Drives & Automation,01-5326-01r3b
FFunctional Description
77
Run/Stop Control [215]
This function is used to select the source for run and stop
commands. This is described on page 118.
Start/stop via analogue signals can be achieved by using
function “Stp<MinSpd [342]”.
Communication information
Reset Control [216]
When the AC drive is stopped due to a failure, a reset
command is required to make it possible to restart the AC
drive. Use this function to select the source of the reset
signal.
Communication information
Default:
Remote
Remote
0
The start/stop signal comes from the digital
inputs of the terminal strip (terminals 1-22).
For settings, see menu group [330] and
[520].
Keyboard
1
Start and stop is set on the Control Panel.
Com
2
The start/stop is set via the serial
communication (RS 485, Fieldbus.) See
Fieldbus or RS232/485 option manual for
details.
Option
3
The start/stop is set via an option.
Modbus Instance no/DeviceNet no:
43015
Profibus slot/index
168/174
EtherCAT index (hex)
4bc7
Profinet IO index
19399
Fieldbus format
UInt
Modbus format
UInt
215 Run/Stp Ctrl
Stp
Remote
Default:
Remote
Remote
0
The command comes from the inputs of
the terminal strip (terminals 1-22).
Keyboard
1
The command comes from the command
keys of the Control Panel.
Com
2
The command comes from the serial
communication (RS 485, Fieldbus).
Keyb
3
The command comes from the inputs of
the terminal strip (terminals 1-22) or the
keyboard.
Com +
Keyb
4
The command comes from the serial
communication (RS485, Fieldbus) or the
keyboard.
Rem+Keyb
+Com
5
The command comes from the inputs of
the terminal strip (terminals 1-22), the
keyboard or the serial communication
(RS485, Fieldbus).
Option
6
The command comes from an option.
Only available if the option can control
the reset command.
Modbus Instance no/DeviceNet no:
43016
Profibus slot/index
168/175
EtherCAT index (hex)
4bc8
Profinet IO index
19400
Fieldbus format
UInt
Modbus format
UInt
216 Reset Ctrl
Stp
Remote
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...