![VEM VEMoDRIVE VSI 2.0 HD Instruction Manual Download Page 75](http://html1.mh-extra.com/html/vem/vemodrive-vsi-2-0-hd/vemodrive-vsi-2-0-hd_instruction-manual_3985886075.webp)
CG Drives & Automation,01-5326-01r3b
FFunctional Description
73
11. Functional Description
This chapter describes the menus and parameters in the
software. You will find a short description of each function
and information about default values, ranges, etc. There are
also tables containing communication information. You will
find the parameter number for all available fieldbus options
as well as the enumeration for the data.
On our home page in the download area, you could find a
"Communication information" list and a list to note
“Parameter set” information.
Description of menu table layout
Following two kinds of tables are used in this chapter.
1. Parameter cannot be changed during operation.
2. Parameter only for viewing.
3. Menu information as displayed on control panel.
For explanation of display text and symbols, see Chapter
9.2 page 63.
4. Factory setting of parameter (also showed on display).
5. Available settings for the menu, listed selections.
6. Communication integer value for the selection.
For use with communication bus interface (only if
selection type parameters).
7. Description of selection alternative, setting or range
(min - max value).
Resolution of settings
The resolution for all range settings described in this chapter
is 3 significant digits. Exceptions are speed values which are
presented with 4 significant digits. Table 26 shows the
resolutions for 3 significant digits.
11.1 Preferred View [100]
This menu is displayed at every power-up. During
operation, the menu [100] will automatically be displayed
when the keyboard is not operated for 5 minutes. The
automatic return function will be switched off when the
Toggle and Stop key is pressed simultaneously. As default it
displays the reference and torque values.
Menu “[100] Preferred View” displays the settings made in
menu “[110], 1st line”, and “[120], 2nd line”. See Fig. 76.
Fig. 76 Display functions
NOTE: Functions marked with the sign
cannot be
changed during Run Mode.
M
Read-only
N
O
Default:
P
Q
o
S
M
Read-only
N
O
Default:
P
Resolution
S
332
Init Torque
Stp
10%
222
Motor Frequ
Stp
M1
50Hz%
Table 26
3 Digit
Resolution
0.01-9.99
0.01
10.0-99.9
0.1
100-999
1
1000-9990
10
10000-99900
100
100
0rpm
Stp
0.0Nm
100
(1st Line)
Stp
(2nd
Line)
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...