![VEM VEMoDRIVE VSI 2.0 HD Instruction Manual Download Page 119](http://html1.mh-extra.com/html/vem/vemodrive-vsi-2-0-hd/vemodrive-vsi-2-0-hd_instruction-manual_3985886119.webp)
CG Drives & Automation,01-5326-01r3b
FFunctional Description
117
Release torque [33I]
The Brake Release Time [33C] sets the time the AC drive
delays before ramping up to whatever final speed reference
value is selected, to allow the brake to be fully opened.
During this time a holding torque to prevent roll-back of the
load can be activated. The parameter Release Torque [33I] is
used for this purpose.
The release torque initiates the torque reference from the
speed controller during the Brake Release Time [33C]. The
release torque defines a minimum level of release (holding)
torque. The set release torque is internally overruled if the
actual required holding torque measured at the previous
closing of brake is higher.
The release torque is set with sign in order to define the
holding torque direction.
Communication information
Fig. 88 Principle of Brake operation for fault during run and during stop
Default:
0%
Range
-400% to 400%
Modbus Instance no/DeviceNet no:
43118
Profibus slot/index
169/22
EtherCAT index (hex)
4c2e
Profinet IO index
19502
Fieldbus format
Long, 1=1%
Modbus format
EInt
33I Release Trq
Stp
0
0%
Note! Function is deactivated if set to 0%.
Note! Release Torque [33I] has priority over torque
reference initialization by Release Speed [33D].
Brake warning
Brake Trip
Brake acknowledge
Brake relay
Speed>0
Torque
Running
Start
During run
During stop
Brake
<33H
33H
<33H
Brake
Brake wait
time
Brake engage
time
33F
33E
33C
33C
release time
release time
Brake Fault trip time
*
**
* Memorized load torque level, if function activated with parameter [33I] Release Torque.
** Time for operator to set down the load.
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...