98
Functional Description
CG Drives & Automation, 01-5326-01r3b
Over current F [25O]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
Pump [25P]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
Over Speed [25Q]
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
External Motor Temperature [25R]
Delay time starts counting when the fault disappears. When
the time delay has elapsed, the alarm will be reset if the
function is active.
Communication information
External Motor Trip Type [25S]
Select the preferred way to react to an alarm trip.
Communication information
Liquid cooling low level [25T]
Delay time starts counting when the fault disappears. When
the time delay has elapsed, the alarm will be reset if the
function is active.
Default:
Off
Off
0
Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no:
43082
Profibus slot/index
168/241
EtherCAT index (hex)
4c0a
Profinet IO index
19466
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Off
Off
0
Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no:
43095
Profibus slot/index
168/254
EtherCAT index (hex)
4c17
Profinet IO index
19479
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Off
Off
0
Off
1–3600 1–3600 1–3600 s
25O Over curr F
Stp
Off
25P Pump
Stp
Off
25Q Over speed
Stp
Off
Modbus Instance no/DeviceNet no:
43096
Profibus slot/index
169/0
EtherCAT index (hex)
4c18
Profinet IO index
19480
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Off
Off
0
Off
1–3600 1–3600 1–3600 s
Modbus Instance no/DeviceNet no:
43097
Profibus slot/index
168/239
EtherCAT index (hex)
4c19
Profinet IO index
19481
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Trip
Selection:
Same as menu [25B]
Modbus Instance no/DeviceNet no:
43098
Profibus slot/index
168/240
EtherCAT index (hex)
4c1a
Profinet IO index
19482
Fieldbus format
UInt
Modbus format
UInt
25R Ext Mot Temp
Stp
Off
25S Ext Mot TT
Stp
Trip
25T LC Level
Stp
Off
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...