Operation via the Control Panel
63
9.
Operation via the Control Panel
This chapter describes how to use the control panel. The AC
drive can be delivered with a control panel or a blank panel.
9.1
General
The control panel displays the status of the AC drive and is
used to set all the parameters. It is also possible to control
the motor directly from the control panel. The control panel
can be built-in or located externally via serial
communication.The AC drive can be ordered without the
control panel. Instead of the control panel there will be a
blank panel.
9.2
The control panel
Fig. 65 Control panel display, LEDs and Keys.
9.2.1
The display
The display is back lit and consists of 2 rows, each with
space for 16 characters. The display is divided into six areas.
The different areas in the display are described below:
Fig. 66 The display
Area A:
Shows the actual menu number (3 or 4
digits).
Area B
Shows if the menu is in the toggle loop or the
AC drive is set for Local operation.
Area C:
Shows the heading of the active menu.
Area D *: Shows the status of the AC drive (3 digits).
The following status indications are possible:
*) The status shown in Area D on the control panel can be
read via a fieldbus or serial communication, e.g. using
Modbus address nr 30053.
It is also possible to read all status indications, not just the
highest prioritized one, via a fieldbus or serial
communication, e.g. using Modbus address nr 30180.
This information is also shown in
7&.
oSoftCom PC-tool
(optional) as menu “Status bits [72B]”.
Area E:
Shows active parameter set and if it is a motor
parameter.
Area F:
Shows the setting or selection in the active menu.
This area is empty at the 1st level and 2nd level
menu. This area also shows warnings and alarm
messages. In some situations this area could
indicate “+++” or ” - - -” please see further
information in Chapter 9.2.2 page 64
NOTE: The AC drive can run without the control panel
being connected. However the settings must be such
that all control signals are set for external use.
LCD display
LEDs
Control Keys
Toggle Key
Function Keys
221
Motor Volt
Stp
M1:
400V
A
C
D
F
B
E
Digits
Description
Bit*
Stp Motor is stopped
0
Run Motor runs
1
Acc Acceleration
2
Dec Deceleration
3
Trp
Tripped
4
SST
Operating Safe Stop, is flashing when
activated
5
VL
Operating at voltage limit
6
SL
Operating at speed limit
7
CL
Operating at current limit
8
TL
Operating at torque limit
9
OT
Operating at temperature limit
10
I
2
t
Active I
2
t protection
11
LV
Operating at low voltage
12
Sby Operating from Standby power supply
13
LCL Operating with low cooling liquid level
14
Slp
Sleep mode
15
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...