11.2.6 Parameter Set Handling [240]
There are four different parameter sets available in the AC
drive. These parameter sets can be used to set the AC drive
up for different processes or applications such as different
motors used and connected, activated PID controller,
different ramp time settings, etc.
A parameter set consists of all parameters with the exception
of the Global parameters. The Global parameters are only
able to have one value for all parameter sets.
Following parameters are Global: [211] Language, [217]
Local Remote, [218] Lock Code, [220] Motor Data, [241]
Select Set, [260] Serial Communication and [21B]Mains
Supply Voltage .
Select Set [241]
Here you select the parameter set. Every menu included in
the parameter sets is designated A, B, C or D depending on
the active parameter set. Parameter sets can be selected from
the keyboard, via the programmable digital inputs or via
serial communication. Parameter sets can be changed during
the run.
If the sets are using different motors (M1 to M4)
the set will be changed only when the motor is stopped.
Communication information
The active set can be viewed with function
[721] VSD status.
Prepare parameter Set when different Motor data
M1 - M4:
1. Select desired parameter Set to be set in [241] A - D.
2. Select “Motor Set [212]” if other than the default Set
M1.
3. Set relevant motor data in the Menu group [220].
4. Set other desired parameter settings to belong to this
parameter Set.
To prepare a Set for another motor, repeat these steps.
Copy Set [242]
This function copies the content of a parameter set into
another parameter set.
NOTE: Actual timers are common for all sets. When a set
is changed the timer functionality will change according
to the new set, but the timer value will stay unchanged.
Default:
A
Selection:
A, B, C, D, DigIn, Com, Option
A
0
Fixed selection of one of the 4 parameter
sets A, B, C or D.
B
1
C
2
D
3
DigIn
4
Parameter set is selected via a digital
input. Define which digital input in menu
“[520] Digital inputs”.
Com
5
Parameter set is selected via serial
communication.
Option
6
The parameter set is set via an option.
Only available if the option can control the
selection.
241 Select Set
Stp
A
Modbus Instance no/DeviceNet no:
43022
Profibus slot/index
168/181
EtherCAT index (hex)
4bce
Profinet IO index
19406
Fieldbus format
UInt
Modbus format
UInt
NOTE: Parameter set cannot be changed during run if
the parameter set includes change of the motor set
(M2-M4). In this case always stop the motor before
changing parameter set.
Default:
A>B
A>B
0
Copy set A to set B
A>C
1
Copy set A to set C
A>D
2
Copy set A to set D
B>A
3
Copy set B to set A
B>C
4
Copy set B to set C
B>D
5
Copy set B to set D
C>A
6
Copy set C to set A
C>B
7
Copy set C to set B
C>D
8
Copy set C to set D
D>A
9
Copy set D to set A
D>B
10
Copy set D to set B
D>C
11 Copy set D to set C
242 Copy Set
Stp
A
>
B
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...