CG Drives & Automation, 01-5326-01r3b
G
Getting Started
47
5.
Getting Started
This chapter is a step by step guide that will show you the
quickest way to get the motor shaft turning. We will show
you two examples, remote control and local control.
We assume that the AC drive is mounted on a wall or in a
cabinet as in the chapter 2. page 13.
First there is general information of how to connect mains,
motor and control cables. The next section describes how to
use the function keys on the control panel. The subsequent
examples covering remote control and local control describe
how to program/set the motor data and run the AC drive
and motor.
5.1
Connect the mains and
motor cables
Dimension the mains and motor cables according to local
regulations. The cable must be able to carry the AC drive
load current.
5.1.1 Mains cables
1. Connect the mains cables as in Fig. 54. The AC drive
has, as standard, a built-in RFI mains filter that complies
with category C3 which suits the Second Environment
standard.
5.1.2 Motor cables
Connect the motor cables as in Fig. 54. To comply with the
EMC directive you have to use screened cables and the
motor cable screen has to be connected on both sides: to the
housing of the motor and the housing of the AC drive.
Fig. 54 Connection of mains and motor cables.
Table 20
Mains and motor connection
L1,L2,L3
PE
Mains supply, 3 -phase
Safety earth
U, V, W
Motor earth
Motor output, 3-phase
WARNING!
In order to work safely the mains earth must
be connected to PE and the motor earth to
.
AC drive
RFI-Filter
Mains
Metal EMC cable
glands
Screened cables
Metal housing
Brake
resistor
(option)
Output
coils
(option)
Metal connector housing
Motor
Metal EMC
cable gland
Mains
9(0R'ULYH 96, 9(0 U
Summary of Contents for VEMoDRIVE VSI 2.0 HD
Page 1: ...Frequency converter VEMoDRIVE VSI 2 0 HD Instruction manual 01 5326 01 04 2018...
Page 2: ......
Page 4: ......
Page 40: ...38 Installation CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 52: ...50 Getting Started CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 64: ...62 EMC and standards CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 142: ...140 Functional Description CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 198: ...196 CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 232: ...230 Technical Data CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 238: ...236 Menu List CG Drives Automation 01 5326 01r3b 9 0R ULYH 96 9 0 U...
Page 243: ...241 9 0R ULYH 96 9 0 U...