Table 54: Basic parameters G2.1
Index
Parameter
Min
Max
Unit
Default
Cust
ID
Description
P2.1.9 *
Nominal current
of the motor
Varies
Varies
A
5.40
113
Find the value In
on the rating plate
of the motor.
P2.1.10
Motor cos phi
0.30
1.00
0.85
120
Find the value on
the rating plate of
the motor.
P2.1.11
I/O reference
0
15/16
0
117
0 = AI1
1 = AI2
2 = AI1+AI2
3 = AI1-AI2
4 = AI2-AI1
5 = AI1xAI2
6 = AI1 Joystick
7 = AI2 Joystick
8 = Keypad
9 = Fieldbus
10 = Motor poten-
tiometer
11 = AI1, AI2 mini-
mum
12 = AI1, AI2 maxi-
mum
13 = Max fre-
quency
14 = AI1/AI2 selec-
tion
15 = Encoder 1
16 = Encoder 2
(NXP only)
P2.1.12
Keypad control
reference
0
9
8
121
Select the fre-
quency reference
input when the
control place is
Panel.
0 = AI1
1 = AI2
2 = AI1+AI2
3 = AI1-AI2
4 = AI2-AI1
5 = AI1xAI2
6 = AI1 Joystick
7 = AI2 Joystick
8 = Keypad
9 = Fieldbus
P2.1.13
Fieldbus control
reference
0
9
9
122
See P2.1.12
MULTI-PURPOSE CONTROL APPLICATION
VACON · 143
24-HOUR S358 (0)201 212 575 · EMAIL: [email protected]