Reference
3Ć4
DG2030 User Manual
2. Create a sequence table as follows:
a. Open the sequence editor with EDIT
!
Make Sequence.
b. If you need, create sub-sequence(s) with EDIT
!
Make Sequence
!
Special
!
Edit Sub-Sequence
!
New.
c.
Compose the lines by inserting the blocks and/or sub-sequences with
EDIT
!
Make Sequence
!
Insert.
d. Define the control conditions in each line with EDIT
!
Make
Sequence
!
Repeat Count and/or the functions of EDIT
!
Make
Sequence
!
Set Enhanced Control.
Once you have created pattern data or sequences, do the following steps to
configure the instrument hardware and set the output parameters:
1. Assign data bits (DATA0 to DATA7) to output channels (CH0 to CH7) with
SETUP
!
Output Condition
!
Assign Condition. By default, DATA0 to
DATA7 are assigned to CH0 to CH7, respectively.
2. Set the pulse high and low levels with SETUP
!
Level Condition.
3. Set the edge slopes and delay with SETUP
!
Timing Condition.
4. Set the output frequency with SETUP
!
Clock.
Output your pattern data using the following steps:
1. Press the START/STOP button on the front panel to start signal output.
2. Press the START/STOP button again to stop output.
Advanced Control for Sequence
Using the event, trigger and run modes, you can control the pattern data output
timing and sequence from an external controller or just pressing the front panel
buttons. For advanced control, do the following steps:
1. Set the trigger wait and/or event jump into each line on the sequence with
the functions of EDIT
!
Make Sequence
!
Set Enhanced Control. See
Sequence described above.
2. Set the trigger parameters with SETUP
!
Trigger.
3. Set the event and/or inhibit parameters with SETUP
!
Output Condition
!
Control Condition.
4. Set the run mode with SETUP
!
Run Mode.
Setups for Output
Outputs
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com