Operating Examples
DG2030 User Manual
2Ć59
15. Create line 3, and then terminate editing.
Menu button
Bottom button
Popup menu
Side button
Front panel
button
With the front panel up arrow button, move the line pointer back to the line 2.
Set Enhanced
Control
Event Jump
(Set to On)
Jump to
3
ENTER
Go Back
The following two steps set the trigger and run mode for output.
16. Set the trigger source to external and trigger interval to off.
Menu button
Bottom button
Popup menu
Side button
Front panel
button
SETUP
Trigger
Source
(Set to Ext)
Interval
State
(Set to Off)
Go Back
17. Set the run mode to Enhanced.
Menu button
Bottom button
Popup menu
Side button
Front panel
button
Run Mode
Enhanced
Note that when the run mode is set to Enhanced, the displayed settings in the
ENHANCED columns of the Make Sequence menu become gray. See
Figure 2-37.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com