Setup Menu
3Ć72
DG2030 User Manual
OE
Data Output
External Inhibit Input
CH 0
Internal
Off
Both
External
Figure 3Ć54: HighĆimpedance control circuit
Level Condition Menu
This menu sets the channel output high and low voltage levels, and whether
output is disabled in the output stopped state.
Determines the output voltage when the data value is 1 (high level state). You
can set the level within the range between –1.25 V and +3.50 V (into 50
W
load).
The difference between the high level and low level voltages must be between
0.25 V and 5 V. The displayed voltages are the voltages when the outputs are
open.
Operation.
Set the output high level
Bottom button
Popup menu
Side button
Level Condition
High (the high level
setting)
Determines the output voltage when the data value is 0 (low level state). You can
set the level within the range between –1.50 V and +3.25 V (into 50
W
load).
The difference between the low level and high level voltages must be between
0.25 V and 5 V. The displayed voltages are the voltages when the outputs are
open.
Operation.
Set the output low level
Bottom button
Popup menu
Side button
Level Condition
Low (the low level
setting)
High
Low