Precautions: 00-8
Using the testers
• Incorrectly connecting the (+) and (–) probes may
cause the inside of the tester to be burnout.
• If the voltage and current are not known, make
measurements using the highest range.
• When measuring the resistance with the multi-circuit
tester (1),
∞
will be shown as 10.00 M
Ω
and “1”
flashes in the display.
• Check that no voltage is applied before making the
measurement. If voltage is applied the tester may be
damaged.
• After using the tester, turn the power off.
Special tool
: 09900–25008 (Multi-circuit tester set)
NOTE
• When connecting the multi-circuit tester,
use the needle pointed probe to the back
side of the lead wire coupler and connect
the probes of tester to them.
• Use the needle pointed probe to prevent
the rubber of the water proof coupler from
damage.
• When using the multi-circuit tester, do not
strongly touch the terminal of the ECM
coupler with a needle pointed tester probe
to prevent the terminal damage or terminal
bend.
Special tool
(A): 09900–25009 (Needle pointed probe set)
I649G1000002-02
(A)
I649G1000025-03