15
» The installation must be carried out in accordance with the standards EN 12453 and EN 12445. The force setting of the
automatic module must be adapted to the gate. The actuator has a built-in safety device to prevent crushing injuries which
consists of a torque control. In any case it is necessary to adjust the torque control to the gate appropriately. To minimize the
risk of injury as far as possible, the force setting of the gate controller must be adapted to the gate as follows.
» After hitting an obstacle the actuator will reverse direction.
» Level 1 is the factory programmed the force setting.
» The safety devices (EN 12978 standard) allow the securing of potentially hazardous areas and protect against
mechanical movement risks, such as crushing, dragging, and shearing injuries. During the programming of the force
setting the safety shut-off will not be active.
» Prior to the execution of any job on the system, the electrical supply must be interrupted.
» For each system it is recommended to use at least one light signal as well as a warning sign which should be connected
to the gate structure.
» Schellenberg disclaims all liability pertaining to the safety and trouble-free operation of the drive, if components are used
on the system which were not supplied by Schellenberg.
» Only original parts from Schellenberg are authorized for use during maintenance.
» The components that are part of the drive system are not allowed to be altered in any way.
» The installer must hand over all information to the operator of the system which concern the manual operation of the
system during emergencies as well as these installation instructions which were supplied with the product.
» Neither children nor adults are allowed to dwell in the immediate vicinity of the gate system during operation.
» The remote controls or other impulse transmitters must be kept out of reach of children to prevent accidental activation
of the actuator.
» A passage between the gate leafs is only allowed when the gate is fully open.
» The operator shouldn‘t perform any repairs or directly intervene on the drive. If this should become necessary, only
contact qualified technical personnel.
» Do not dispose of used batteries in the domestic trash! Appropriate collection-boxes are available in certain retailer
localities.
» All procedures that are not expressly provided in these instructions are not permitted.
» The commissioning of the gate system is prohibited until it has been determined that the gate system complies with the
provisions of all relevant applicable regulations and EU directives.
Assembly und operating instructions
To ensure the necessary security and the smooth operation of the actuators, the following preconditions must be checked:
» The installation of the electronic control unit housings must be performed with such a distance from the drives, that the
motor cables will not require an extension in any case.
» For use in masonry or concrete posts, we recommend using chemical anchor bolts or anchor bolts which guarantee a
stress-free mounting.
» The gate must be suitable for the actuator system. It must especially be ensured that it is sufficiently strong and rigid. For metal
gate leafs we recommend establishing the connection to the actuators with screws. For wooden gates the fixing screws must
be fully supported on the inside and outside with metal plates, since otherwise the screws could loosen over time.
» The dimensions and weights must match the specifications of the technical properties.
» Check for the smooth and uniform movement of the leafs and make sure that there is no friction or obstructions during
the entire movement.
» Also ensure the perfect condition of the hinges.
» Mechanical end stops in the position “door closed” must be present.
» Remove the existing locks and blocking devices. It is recommended that any blacksmithing be carried out before
mounting the actuators.
» Please observe that, depending on the opening angle, there must be an adequate space for the motion range of the gate.
After the installation
» The passage between the leafs is prohibited as long as they are in motion. Before passing through the gate leafs, the
gate should be opened completely.
» The dwelling of persons between the leafs is strictly prohibited.
Summary of Contents for TWIN 300
Page 1: ...TWIN 300...
Page 2: ......
Page 132: ...132 Schellenberg Schellenberg Schellenberg Tor geschlossen 136...
Page 141: ...141 Schellenberg Schellenberg Schellenberg 145...
Page 159: ...159 Schellenberg Schellenberg Schellenberg...
Page 168: ...168 Schellenberg 172...
Page 258: ...258...
Page 274: ...1x 1x 1x 274...
Page 275: ...4x 2x Art No 60852 60853 2x 4x 1x 3x 2x2 1x 2x 1x2m 1 2 1x7m 275...
Page 277: ...7m 2m 277...
Page 278: ...Min 150mm Max 116mm Min 70mm 278...
Page 281: ...Min 70mm 281...
Page 282: ...2x B 282 1...
Page 283: ...283 3 2...
Page 284: ...284 4...
Page 285: ...285 5...
Page 286: ...286 6...
Page 287: ...287 7...
Page 288: ...288 8...
Page 289: ...289 9...
Page 290: ...290 10...
Page 291: ...2x 291 11...
Page 292: ...292 12 13...
Page 293: ...276 294 294 293...
Page 294: ...4x 3x 294 14 16 17 15...
Page 295: ...LED1 LED5 LED2 LED3 LED4 3x 295 18...
Page 296: ...1 2 3x 2x 296 19...
Page 297: ...L L Lo Lo 12V G F01 F02 F0 G D S G Mo1 Mo1 Mo2 Mo2 LED5 297 20...
Page 302: ...LED1 LED5 LED2 LED3 LED4 12V G F01 F02 F0 G D S G LED5 C 4 302...
Page 304: ...LED1 LED5 LED2 LED3 LED4 12V G F01 F02 F0 G D S G A LED5 C 5 304...
Page 305: ...307 306 305...
Page 310: ...LED1 LED5 LED2 LED3 LED4 12V G F01 F02 F0 G D S G C 8 310...
Page 311: ...10sec LED5 1 10 sec 311...
Page 312: ...D 312...
Page 314: ...Mo1 Mo1 Mo2 Mo2 L L Lo Lo 12V G F01 F02 F0 G D S G Art No 60999 60997 LED5 G SW1 SW2 SW3 E 314...