Set Trig Source to Bus.
4.2.7.10 Samp Clock [Int/Ext]
Functional Description:
This command sets ARB Samp Clock. When Samp Clock is Int, the clock frequency is 200 MHz.
It cannot be changed. When Int is Ext, the clock frequency can be set by the external clock frequency
command.
Parameter specification:
<Mode> Discrete data. ARB Samp Clock is as follows:
INTernal : Internal,
EXTernal : EXT.
Programmable command:
[:SOURce]:RADio:ARB:VCO:CLCOk INTernal|EXTernal
[:SOURce]:RADio:ARB:VCO:CLOCk?
Example:
[:SOURce]:RADio:ARB:VCO:CLOCk EXTernal
Set Trig Source to Bus.
4.2.7.11 Ext Clock Frequency
Functional Description:
This command sets Ext Clock Frequency. This command is valid when Samp Clock is Ext.
Parameter specification:
<Mode>
ARB Samp Clock is as follows:
Range [100Hz,250MHz]
Programmable command:
[:SOURce]:RADio:ARB:EXTernal:CLCOk:RATE
<val><freq unit>
[:SOURce]:RADio:ARB:EXTernal:CLOCk:RATE?
Example:
[:SOURce]:RADio:ARB:EXTernal:CLOCk:RATE
100MHz
Set Trig Source to Bus.
4.2.7.12 Wave Scale
Functional Description:
Not supported
4.2.7.13 Wave Realtime Scale
Functional Description:
Not supported
4.2.7.14 Wave Attenuation
Functional Description:
Not supported
4.2.7.15 Marker Polary F
Functional Description:
Not supported
4.2.7.16 Marker Function