Instruction Manual
IM-106-880, Rev 2.1
April 2017
OCX 8800
7-14
COMB
_SENSOR_CAL_WHO
COMB_AUTOCAL_
INTERVAL
See FF-903 section 3.3.
0-9999
Hours
The time between automatic calibrations of the combustibles sensor.
COMB_CAL_POINT
0-55000
PPM
The value of the combustibles test gas.
COMB_CONSTANT
-99.0-99.0
PPM
The combustibles calibration constant.
COMB_DELTA_
RESISTANCE
Ohms
The raw value of the combustibles level input. This is the difference
between the active and reference RTDs.
COMB_FAILED_CONSTANT
PPM
This is the constant value calculated from the last failed Combustibles
calibration.
COMB_FAILED_SLOPE
PPM/Ohm
This is the slope value calculated from the last failed Combustibles
calibration.
COMB_HTR_DUTYCYCLE
Combustibles heater duty cycle.
COMB_PERCENT_OF_
RANGE
COMB_PREVIOUS_
CONSTANT
%
The percent of range of the current combustibles reading.
PPM
The combustibles calibration constant from the previous good calibration.
COMB_PREVIOUS_SLOPE
PPM/Ohm
The combustibles calibration slope from the previous good calibration.
COMB_PRIMARY_VALUE
The value and status of the combustibles concentration reading.
COMB_PRIMARY_VALUE_
RANGE
COMB_PRIMARY_VALUE_
TYPE
COMB_REFERENCE_
OHMS
COMB_SECONDARY_
VALUE
COMB_SECONDARY_
VALUE_RANGE
COMB_SENSOR_CAL_
DATE
COMB_SENSOR_
EXCITATION
See FF903
section 4.1
The High and Low range limit values, the engineering units code, and the
number of digits to the right of the decimal point for the combustibles
reading.
See FF-903 section 3.3.
Ohms
The raw value of the combustibles reference input.
The combustibles cell temperature. This is the determined from the value
of the combustibles reference RTD.
The High and Low range limit values, the engineering units code, and the
number of digits to the right of the decimal point for the combustibles cell
temperature reading.
See FF-903 section 3.3.
mA
Combustible Reference current.
COMB_SENSOR_TYPE
See FF-903 section 3.3 and 4.3.
COMB_SETPOINT
°
C
Combustibles heater temperature set point.
COMB_SLOPE
200-4500
PPM/Ohm
The combustibles calibration slope.
COMB_SLOPE_WARNING
25.0-99.0
% of FS
The combustible slope warning threshold.
COMB_T90
0-300
Seconds
The amount of time that the combustibles process variable will take to
reach 90% of the actual process variable.
COMB_TEMP_MAX
°C
The highest Combustibles temperature read since power on.
COMB_THERMOCOUPLE_
INPUT
COMB_TIME_TO_NEXT_
CAL
mV
Combustible Block T/C voltage (Valid only with Type 3 sensor).
0-9999
Hours
The time until the next automatic calibration of the combustibles sensor.
COMB_TOL_CHECK
0: No
– 1: Yes
Combustible calibration gas tolerance check.
COZERO_DURATION
120-600
Seconds
The duration of the Combustibles sensor zero cycle.
COZERO_ENABLED
0: Off
– 1: On
Enumerated
Indicates whether Combustibles sensor zero is enabled.
COZERO_INTERVAL
60-480
Minutes
The time between Combustibles sensor zero cycles.
COZERO_OUTTRAK
0, 1, 2, 3
Enumerated
Indicates whether the Combustibles analog output should track the input
during Combustibles sensor zero or lock at the last process reading.
(0=None, 1=O
2
, 2=CO
2
, 3= Both)
Parameter Mnemonic
Valid Range
Units
Description
Summary of Contents for OCX 8800
Page 2: ......
Page 4: ......
Page 10: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 ii ...
Page 72: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 4 8 ...
Page 88: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 5 16 ...
Page 100: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 6 12 ...
Page 164: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 7 64 ...
Page 176: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 8 12 ...
Page 213: ......
Page 223: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 10 11 ...
Page 225: ......
Page 262: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 C 2 ...