Table 1-1. Product Matrix - OCX 8800
OCX88A
O
2
/Combustibles Transmitter
Code
Probe Length and Material
00
No Probe or Exhaust Tube
11
18 in. (457 mm) 316 SST
up to 1300°F (704°C)
12
3 ft (0.91 m) 316 SST
up to 1300°F (704°C)
13
6 ft (1.83 m) 316 SST
up to 1300°F (704°C)
14
9 ft (2.7 m) 316 SST
up to 1300°F (704°C)
21
18 in. (457 mm) Inconel 600
up to 1832°F (1000°C)
22
3 ft (0.91 m) Inconel 600
up to 1832°F (1000°C)
23
6 ft (1.83 m) Inconel 600
up to 1832°F (1000°C)
24
9 ft (2.7 m) Inconel 600
up to 1832°F (1000°C)
31
18 in. (457 mm) Ceramic
up to 2600°F (1427°C)
32
3 ft (0.91 m) Ceramic
up to 2600°F (1427°C)
Code
Probe Mounting Assembly
10
(ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes - Standard O2 Cell
11
(ANSI 2 in. 150 lb) 6" dia. flange, 4.75" BC with 4 x 0.75" dia. holes - High Sulfur O2 Cell
20
(DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes - Standard O2 Cell
21
(DIN) 185 mm dia. flange, 145 mm BC with 4 x 18 mm dia. holes - High Sulfur O2 Cell
Code
Mounting Hardware - Stack Side
0
No Adapter Plate (“0” must be chosen under “Mounting Adapter - Probe Side” below)
1
New Installation - Square weld plate with studs
2
Model 218/240 Mounting Plate (with Model 218/240 Shield Removed)
3
Existing Model 218/240 Support Shield
4
Competitor’s Mount
(1)
5
Model 132 Adapter Plate
Code
Mounting Hardware - Probe Side
0
No Adapter Plate
1
Probe Only (ANSI)
4
Probe Only (DIN)
Code
Electronics Housing - NEMA 4X, IP66 HART Communications
H1
HART Communications - Basic Unit
H2
HART Communications - Local Operator Interface
H3
HART Communications - Calibration Solenoids
H4
HART Communications - Local Operator Interface and Calibration Solenoids
F1
Fieldbus Communications - Basic Unit
F2
Fieldbus Communications - Local Operator Interface
F3
Fieldbus Communications - Calibration Solenoids
F4
Fieldbus Communications - Local Operator Interface and Calibration Solenoids
Code
Electronics Mounting
01
Integral to Sensor Housing Electronics
02
Split Architecture with no cable
03
Split Architecture with 6M (20 Ft.) cable
04
Split Architecture with 12M (40 Ft.) cable
05
Split Architecture with 18M (60 Ft.) cable
06
Split Architecture with 24M (80 Ft.) cable
07
Split Architecture with 30M (100 Ft.) cable
08
Split Architecture with 45M (150 Ft.) cable
OCX88A
11
10
1
1
H3
06
Example
Summary of Contents for OCX 8800
Page 2: ......
Page 4: ......
Page 10: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 ii ...
Page 72: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 4 8 ...
Page 88: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 5 16 ...
Page 100: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 6 12 ...
Page 164: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 7 64 ...
Page 176: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 8 12 ...
Page 213: ......
Page 223: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 10 11 ...
Page 225: ......
Page 262: ...Instruction Manual IM 106 880 Rev 2 1 April 2017 OCX 8800 C 2 ...